COLCHESTER DEVELOPMENT REGULATIONS

SUPPLEMENT 48

Article 4: GENERAL DEVELOPMENT DISTRICTS

General Development districts provide for residential and compatible commercial uses featuring convenience of required facilities and services. Such mixing occurs either within a shared structure, neighborhood, or zoning district, as prescribed.

4.01 General Development One (GD1)

4.01–A     Purpose. To provide for residential and compatible commercial uses in the Colchester Village and Warner’s Corners neighborhoods.

4.01–B     Additional Standards.

(1)     Multi-unit dwellings shall be subject to Planned Residential Development Review, as per Article 9.

(2)     Residential units and commercial uses may be permitted to occupy the same building subject to the Conditional Use and Site Plan criteria and the following standards:

(a)     Qualifying commercial uses shall be limited to: convenience stores without gas sales, general merchandise less than 10,000 sq. ft. no drive-up, retail food establishment with store area less than 5,000 sq. ft., automotive accessory sales without installation, general office, medical office less than 10,000 sq. ft., financial institution, personal or business service, artist production studio, cultural facilities less than 500 sq. ft., nursing care home, day-care facilities, or standard restaurants.
(b)    The residential units shall have an entrance separate from the proposed commercial use.
(c)     Multiple commercial uses within the building may be considered however the commercial uses shall not adversely affect the proposed residential units.  Hours of operation of the commercial uses may be restricted to ensure no adverse effect to the residences.
(d)    Residential units converted from non-residential square footage in existence prior to January 1, 2004 under this section shall not be subject to Planned Residential Development review.

4.02  General Development Two (GD2)

4.02–A     Purpose. To provide a range of commercial, light industry and compatible multi-unit dwellings and related uses for the Fort Ethan Allen neighborhood and vicinity.

4.02–B     Additional Standards.

(1)     Multi-unit dwellings, in addition to the Planned Residential Development criteria contained in Article 9, shall be subject to the following standards:

(a)     Class one properties, or properties with municipal water and municipal sewer, shall have a maximum residential density of ten (10) dwelling units per acre unless otherwise provided through the use of transfer of development rights under Section 7.06 herein.
(b)    Class two properties, or properties with municipal water and on-site septic, shall have a maximum residential density of four (4) dwelling units per acre.

(2)     Outside storage for any use shall be confined to the rear yard and shall be screened from view from any side by a sufficiently high wall or fence or by appropriate landscaping such as berms, hedges and /or shrubbery.

(3)     All equipment maintenance, repair or manufacturing operations shall be within enclosed structures.

4.03 General Development 3 GD3/Severance Corners Form-Based (FB) District

4.03–A     Purpose. To facilitate a development pattern and interconnected street network within the Severance Corners Form-Based District that is modeled on traditional New England downtowns. The district shall be characterized by higher-density, mixed-use, multi-story buildings that can accommodate retail, office, commercial, light industrial, civic and residential uses. It shall have buildings set close to the sidewalk with entrances, storefronts and windows facing the street. Streets with curbs, street trees and sidewalks shall define small- to medium-sized blocks.

4.03–B     Allowed Uses. Those uses indicated in Table 1 (below) and accessory uses to those uses. Any uses not listed in Table 1 are prohibited. Items that are not customary as accessory uses to those listed in Table 1 are prohibited. Table 1 (below) includes classes of uses (i.e. office); refer to Table A-1: Table of Uses for a detailed list of uses within each class (i.e. general office, research facility or laboratory, medical office).  

4.03–C     Establishment of Street Types. Development under the form-based code for this district shall be regulated by street type. Three street types are established, in order from highest to lowest: A Streets, B Streets, and C Streets. When the streets intersect, the primary street frontage is the highest order street type. The front of a principal building and its main entrance shall face the primary street frontage.

4.03–D     Classification of Streets. U.S. Route 7 & 2, Blakely Road and Severance Road shall be A Streets. The classification of any new public or private streets serving development within this district shall be approved by the Town of Colchester at the time of subdivision or site plan approval. Not more than 50% of the total length of new streets within any development shall be classified as a C Street.

4.03–E     Block Standards. No block, which includes an A or B Street, shall exceed a total perimeter length of 1,600 feet. Any block side on an A or B Street longer than 400 feet shall be broken up by a right-of-way allowing, at a minimum, through pedestrian connections.

4.03–F      Development Standards. All development in the Severance Corners Form-Based District shall be subject to the standards set forth in Tables 2-6 below.

4.03–G     Definitions. Terms specific to this section are defined as follows:

Frontage Buildout. Frontage buildout shall be calculated based on the widest point of a building between the minimum and maximum front setback lines and the width of the lot at the front lot line.

4.03–H      Maintenance Structures

(1)     Maintenance Structures, as defined herein, may exist as the sole structure on a lot without meeting the street dimensional and architectural standards that would otherwise apply to principal structures.

(2)      Maintenance structures shall be clearly intended to service a recreational amenity or serve as a maintenance storage function on the site.

(3)     They shall not exceed 3000 square feet in gross floor area, nor twenty-five (25) feet in height and shall be limited to no more than three (3) per Planned Unit Development.

(4)     Maintenance structures shall be compatible to adjacent buildings in material, color, and design.

(5)     Maintenance structures shall not be located between the street line and the front building line of any principal building and shall be located a minimum of fifteen (15) feet from all lot lines.

 

 

 


 

Table 4-1. Allowed Uses in GD3/FB District

USE:

(SEE SUPPLEMENT 30 [TABLE A-1: TABLE OF USES]  FOR A DETAILED LIST OF USES WITHIN EACH CLASS)

A STREET

B STREET

C STREET

GROUND FLOOR

UPPER FLOOR

GROUND FLOOR

UPPER FLOOR

GROUND FLOOR

UPPER FLOOR

1.100

Single-Unit Dwelling

 

P

P

1.200

Duplex Dwelling

 

P

P

1.300

Multi-Unit Dwelling

 

P

C

P

P

P

1.400

Dwellings (w/ services, care or treatment)

P

P

P

P

P

P

1.530

Hotel & Motel

P

P

P

P

1.540

Extended Stay Hotel

P

P

P

P

P

P

1.550

Inn

P

P

P

P

P

P

1.600

Temporary Residences

 

P

P

P

P

1.700

Home Businesses

 

P

P

P

P

2.110

Convenience Store

P

P

2.120

Shopping Center

P

P

P

P

2.130

Retail Sales

P

P

P

P

2.140

Retail Food Establishment

P

P

P

P

2.150

Wholesale Establishment

 

P

P

2.610

General Merchandise Rental

P

P

3.100

Office

P

P

P

P

P

3.200

General Services

P

P

P

P

P

4.100

Manufacturing (fully enclosed)

 

 

P

P

5.000

Edu., Cultural, Religious & Social Uses

P

P

P

P

P

P

6.100

Recreation & Entertainment (indoor)

P

P

P

P

6.210

Private Recreational Facilities

P

P

P

P

P

P

6.220

Public Outdoor Recreation

P

P

P

6.300

Coliseums and Stadiums

P

P

P

P

7.000

Institutional Residence & Care Facilities

 

P

P

P

8.000

Restaurants, Bars & Nightclubs

P

P

P

P

9.100

Automobile Parking

P

P

P

P

9.230

Archival Facility

 

P

P

P

9.240

Distribution Facility

 

C

C

11.030

Public & Semi-Public Facilities

P

P

P

P

P

P

11.300

Transit Center

 

C

C

11.400

Public Garage

P

P

P

P

11.500

Municipal Services

P

P

P

P

11.800

Post Office

P

P

P

P

11.900

Essential Service Facility

P

P

P

P

P

P

12.000

Towers and Related Structures

 

P

P

13.000

Temporary Structures

P

P

P

P

14.000

PUDs

P

P

P

P

P

P

 


 

Table 4-2. A Street Dimensional Standards

A Streets are lined with mixed-use, multi-story storefront buildings that are positioned at the front of each lot. The following standards shall apply to all lots and buildings fronting on an A Street:

 

 

 

 

Text Box: 1Additional Front Setbacks 1. Setbacks are provided accordingly: a. 10 feet per additional story over two stories, never to exceed 50 feet from the road right of way. 2. The space within the front setback must be programmed as follows: a. No parking shall be permitted. b. No access drives shall be permitted in front of the building unless as a circulation lane required by Town Emergency service directors in consultation with the Director of Planning and Zoning. c. The space shall serve as a civic amenity for the adjacent buildings and shall be thoughtfully landscaped. The space shall be open and usable to the tenants of the adjacent buildings and shall be attractive, welcoming and inviting. Additional, low-height street trees are encouraged. d. Year-round, fixed seating shall be provided. e. The area may be used for outdoor space for the ground-floor non-residential spaces, including café seating and limited, organized retail display areas which do not impede pedestrian movements. 3. The Development Review Board has the ability to grant additional setbacks, with the minimum reasonable relief, where there is substantiated confidence that a near-term future widening of the right-of-way on these named roads will cause reduced setback once built. " v:shapes="AutoShape_x0020_14">

2.A Lot Configuration

 

A

Lot width

20 ft min, 180 ft max

 

B

Lot depth

80 ft min

 

C

Lot coverage

90% max

D

Frontage buildout

60% min

2.B Building Placement

Principal Building

E

Front setback

5 ft min, 25 ft max1

F

Side setback

0 ft min

G

Rear setback

12 ft min

Accessory Building

H

Front setback

20 ft + principal bldg. setback min

 

I

Side setback

3 ft min

 

Article 4: GENERAL DEVELOPMENT DISTRICTS
Published by ClerkBase